8,457 research outputs found
Sound propagation in and low frequency noise absorption by helium-filled porous material
Low-frequency noise is difficult to deal with by traditional porous material due to its inherent high acoustic impedance. This study seeks to extend the effective range of sound absorption to lower frequencies by filling a low density gas, such as helium, in the porous material. Compared with conventional air-filled absorption material, the helium-filled porous material has a much reduced characteristic impedance; hence, a good impedance matching with pure air becomes more feasible at low frequencies. The acoustic properties of a series of helium-filled porous materials are investigated with a specially designed test rig. The characteristic of the sound propagation in a helium-filled porous material is established and validated experimentally. Based on the measured acoustic properties, the sound absorption performance of a helium-filled absorber (HA) of finite thickness is studied numerically as well as experimentally. For a random incidence field, the HA is found to perform much better than the air-filled absorber at low frequencies. The main advantage of HA lies in the middle range of oblique incidence angles where wave refraction in the absorber enhances sound absorption. The advantage of HA as duct lining is demonstrated both numerically and experimentally. © 2009 Acoustical Society of America.published_or_final_versio
Single-trial detection of visual evoked potentials by common spatial patterns and wavelet filtering for brain-computer interface
Event-related potentials (ERPs) are widely used in brain-computer interface (BCI) systems as input signals conveying a subject's intention. A fast and reliable single-trial ERP detection method can be used to develop a BCI system with both high speed and high accuracy. However, most of single-trial ERP detection methods are developed for offline EEG analysis and thus have a high computational complexity and need manual operations. Therefore, they are not applicable to practical BCI systems, which require a low-complexity and automatic ERP detection method. This work presents a joint spatial-time-frequency filter that combines common spatial patterns (CSP) and wavelet filtering (WF) for improving the signal-to-noise (SNR) of visual evoked potentials (VEP), which can lead to a single-trial ERP-based BCI.published_or_final_versio
The incidence of liver injury in Uyghur patients treated for TB in Xinjiang Uyghur autonomous region, China, and its association with hepatic enzyme polymorphisms nat2, cyp2e1, gstm1 and gstt1.
BACKGROUND AND OBJECTIVE: Of three first-line anti-tuberculosis (anti-TB) drugs, isoniazid is most commonly associated with hepatotoxicity. Differences in INH-induced toxicity have been attributed to genetic variability at several loci, NAT2, CYP2E1, GSTM1and GSTT1, that code for drug-metabolizing enzymes. This study evaluated whether the polymorphisms in these enzymes were associated with an increased risk of anti-TB drug-induced hepatitis in patients and could potentially be used to identify patients at risk of liver injury. METHODS AND DESIGN: In a cross-sectional study, 2244 tuberculosis patients were assessed two months after the start of treatment. Anti-TB drug-induced liver injury (ATLI) was defined as an ALT, AST or bilirubin value more than twice the upper limit of normal. NAT2, CYP2E1, GSTM1 and GSTT1 genotypes were determined using the PCR/ligase detection reaction assays. RESULTS: 2244 patients were evaluated, there were 89 cases of ATLI, a prevalence of 4% 9 patients (0.4%) had ALT levels more than 5 times the upper limit of normal. The prevalence of ATLI was greater among men than women, and there was a weak association with NAT2*5 genotypes, with ATLI more common among patients with the NAT2*5*CT genotype. The sensitivity of the CT genotype for identifying patients with ATLI was 42% and the positive predictive value 5.9%. CT ATLI was more common among slow acetylators (prevalence ratio 2.0 (95% CI 0.95,4.20) )compared to rapid acetylators. There was no evidence that ATLI was associated with CYP2E1 RsaIc1/c1genotype, CYP2E1 RsaIc1/c2 or c2/c2 genotypes, or GSTM1/GSTT1 null genotypes. CONCLUSIONS: In Xinjiang Uyghur TB patients, liver injury was associated with the genetic variant NAT2*5, however the genetic markers studied are unlikely to be useful for screening patients due to the low sensitivity and low positive predictive values for identifying persons at risk of liver injury
Single-trial laser-evoked potentials feature extraction for prediction of pain perception
Pain is a highly subjective experience, and the availability of an objective assessment of pain perception would be of great importance for both basic and clinical applications. The objective of the present study is to develop a novel approach to extract pain-related features from single-trial laser-evoked potentials (LEPs) for classification of pain perception. The single-trial LEP feature extraction approach combines a spatial filtering using common spatial pattern (CSP) and a multiple linear regression (MLR). The CSP method is effective in separating laser-evoked EEG response from ongoing EEG activity, while MLR is capable of automatically estimating the amplitudes and latencies of N2 and P2 from single-trial LEP waveforms. The extracted single-trial LEP features are used in a Naïve Bayes classifier to classify different levels of pain perceived by the subjects. The experimental results show that the proposed single-trial LEP feature extraction approach can effectively extract pain-related LEP features for achieving high classification accuracy.published_or_final_versio
A clinically relevant in vivo model for the assessment of scaffold efficacy in abdominal wall reconstruction
Copyright © The Author(s) 2017. An animal model that allows for assessment of the degree of stretching or contraction of the implant area and the in vivo degradation properties of biological meshes is required to evaluate their performance in vivo. Adult New Zealand rabbits underwent full thickness subtotal unilateral rectus abdominis muscle excision and were reconstructed with the non-biodegradable Peri-Guard®, Prolene® or biodegradable Surgisis® meshes. Following 8 weeks of recovery, the anterior abdominal wall tissue samples were collected for measurement of the implant dimensions. The Peri-Guard and Prolene meshes showed a slight and obvious shrinkage, respectively, whereas the Surgisis mesh showed stretching, resulting in hernia formation. Surgisis meshes showed in vivo biodegradation and increased collagen formation. This surgical rabbit model for abdominal wall defects is advantageous for evaluating the in vivo behaviour of surgical meshes. Implant area stretching and shrinkage were detected corresponding to mesh properties, and histological analysis and stereological methods supported these findings.This study was financially supported by the Enterprise Ireland (Technology Development Grant). This publication has emanated from research conducted with the financial support of Science Foundation Ireland (SFI) and is co-funded under the European Regional Development Fund under grant no. 13/RC/2073. This study was also supported by the Centre for Microscopy & Imaging funded by NUI Galway and PRTLI, Cycles 4 and 5, National Development Plan 2007–2013
Artifact mitigation of ptychography integrated with on-the-fly scanning probe microscopy
We report our experiences with conducting ptychography simultaneously with the X-ray fluorescence
measurement using the on-the-fly mode for efficient multi-modality imaging. We demonstrate
that the periodic artifact inherent to the raster scan pattern can be mitigated using a
sufficiently fine scan step size to provide an overlap ratio of >70%. This allows us to obtain transmitted
phase contrast images with enhanced spatial resolution from ptychography while maintaining
the fluorescence imaging with continuous-motion scans on pixelated grids. This capability
will greatly improve the competence and throughput of scanning probe X-ray microscopy
Performance evaluation of Bragg coherent diffraction imaging
In this study,we present a numerical framework for modeling three-dimensional (3D) diffraction data
in Bragg coherent diffraction imaging (BraggCDI) experiments and evaluating the quality of obtained
3D complex-valued real-space images recovered by reconstruction algorithms under controlled
conditions. The approach is used to systematically explore the performance and the detection limit of
this phase-retrieval-based microscopy tool. The numerical investigation suggests that the superb
performance of Bragg CDI is achieved with an oversampling ratio above 30 and a detection dynamic
range above 6 orders. The observed performance degradation subject to the data binning processes is
also studied. This numerical tool can be used to optimize experimental parameters and has the
potential to significantly improve the throughput of Bragg CDI method
Structure-Induced Reversible Anionic Redox Activity in Na Layered Oxide Cathode
Anionic redox reaction (ARR) in lithium- and sodium-ion batteries is under hot discussion, mainly regarding how oxygen anion participates and to what extent oxygen can be reversibly oxidized and reduced. Here, a P3-type Na0.6[Li0.2Mn0.8]O2 with reversible capacity from pure ARR was studied. The interlayer O-O distance (peroxo-like O-O dimer, 2.506(3) Å), associated with oxidization of oxygen anions, was directly detected by using a neutron total scattering technique. Different from Li2RuO3 or Li2IrO3 with strong metal-oxygen (M-O) bonding, for P3-type Na0.6[Li0.2Mn0.8]O2 with relatively weak Mn-O covalent bonding, crystal structure factors might play an even more important role in stabilizing the oxidized species, as both Li and Mn ions are immobile in the structure and thus may inhibit the irreversible transformation of the oxidized species to O2 gas. Utilization of anionic redox reaction (ARR) on oxygen has been considered as an effective way to promote the charge-discharge capacity of the layered oxide cathodes for lithium- or sodium-ion batteries. The detailed mechanism of ARR, in particular how crystal structure affects and coordinates with the ARR, is not yet well understood. In the present work, a combination of X-ray and neutron total scattering measurements has been performed to study the structure of the prototype P3-type layered Na0.6[Li0.2Mn0.8]O2 with pure ARR. Unique structural characteristics, rather than prevailing knowledge of covalency of metal-oxygen, enable the stabilization of the crystal structure of Na0.6[Li0.2Mn0.8]O2 along with the ARR. This work suggests that reversible ARR can be manipulated by proper structure designs, thus to achieve high lithium or sodium storage in layered oxide cathodes. For P3-type Na0.6[Li0.2Mn0.8]O2 with relatively weak Mn-O covalent bonding, crystal structure factors play an important role in stabilizing the oxidized species, inhibiting the irreversible transformation of the oxidized species to O2 gas. The finding is important for better design of layered oxide positive materials with higher reversible capacity via the introduction of a reversible anionic redox reaction
Effects of serum proteins on corrosion behavior of ISO 5832–9 alloy modified by titania coatings
Stainless steel ISO 5832–9 type is often used to
perform implants which operate in protein-containing physiological
environments. The interaction between proteins and
surface of the implant may affect its corrosive properties. The
aim of this work was to study the effect of selected serum
proteins (albumin and γ-globulins) on the corrosion of ISO
5832–9 alloy (trade name M30NW) which surface was modified
by titania coatings. These coatings were obtained by sol–
gel method and heated at temperatures of 400 and 800 °C. To
evaluate the effect of the proteins, the corrosion tests were
performed with and without the addition of proteins with
concentration of 1 g L−1 to the physiological saline solution
(0.9 % NaCl, pH 7.4) at 37 °C. The tests were carried out
within 7 days. The following electrochemical methods were
used: open circuit potential, linear polarization resistance, and
electrochemical impedance spectroscopy. In addition, surface
analysis by optical microscopy and X-ray photoelectron spectroscopy
(XPS) method was done at the end of weekly corrosion
tests. The results of corrosion tests showed that M30NW
alloy both uncoated and modified with titania coatings exhibits
a very good corrosion resistance during weekly exposition
to corrosion medium. The best corrosion resistance in
0.9 % NaCl solution is shown by alloy samples modified by
titania coating annealed at 400 °C. The serumproteins have no
significant effect onto corrosion of investigated biomedical
steel. The XPS results confirmed the presence of proteins on
the alloy surface after 7 days of immersion in proteincontaining
solutions.The investigations were supported by the National Science Centre project No. N N507 501339. The authors gratefully acknowledge Dr. Janusz
Sobczak and Dr. hab. Wojciech Lisowski from Institute of Physical
Chemistry of PAS for XPS surface analyses
- …
