1,340 research outputs found

    Moxifloxacin: Clinically compatible contrast agent for multiphoton imaging

    Get PDF
    Multiphoton microscopy (MPM) is a nonlinear fluorescence microscopic technique widely used for cellular imaging of thick tissues and live animals in biological studies. However, MPM application to human tissues is limited by weak endogenous fluorescence in tissue and cytotoxicity of exogenous probes. Herein, we describe the applications of moxifloxacin, an FDA-approved antibiotic, as a cell-labeling agent for MPM. Moxifloxacin has bright intrinsic multiphoton fluorescence, good tissue penetration and high intracellular concentration. MPM with moxifloxacin was demonstrated in various cell lines, and animal tissues of cornea, skin, small intestine and bladder. Clinical application is promising since imaging based on moxifloxacin labeling could be 10 times faster than imaging based on endogenous fluorescence.1152sciescopu

    Analysis of Slab and Slab Heater Cover in a Compact Endless Cast and Rolling Mill Process using Finite Element Methods

    Get PDF
    Compact Endless cast and rolling Mill (CEM) processes were developed and used to fabricate steel products such as steel slabs. However, the coiling furnace in this process was very expensive, so a new layout was suggested. As the coiling furnace was removed, the interval among the slab heaters had to be increased. This led to a temperature drop in the slab. The temperature distribution of the slab impacts quality, so new layout was developed. This paper presents a Finite Element Method (FEM) simulation of thermal behavior in the slab employing slab heater covers. All of the simulation results were verified by comparing them with experimental results. The slab moving distance at which the temperature was saturated during the process was determined to consider the steady-state and analyze the temperature distribution of the slab and slab heater. Those results revealed that the efficiency of heat conservation increased by more than 50% using the slab heater cover. Finally, a sensitivity analysis of the slab heater cover was conducted with respect to the cover design. The effects of insulator thickness, the gap distance between the slab and cover, and material parameters such as density, and specific heat were investigated to optimize the design of the slab heater cover to produce the best quality slab.11Ysciescopuskc

    Hierarchical microchanneled scaffolds modulate multiple tissue-regenerative processes of immune-responses, angiogenesis, and stem cell homing

    Get PDF
    Recapitulating the in vivo microenvironments of damaged tissues through modulation of the physicochemical properties of scaffolds can boost endogenous regenerative capacity. A series of critical events in tissue healing including immune-responses, angiogenesis, and stem cell homing and differentiation orchestrate to relay the regeneration process. Herein, we report hierarchically structured (‘microchanneled’) 3D printed scaffolds (named ‘μCh’), in contrast to conventional 3D printed scaffolds, induce such cellular responses in a unique way that contributes to accelerated tissue repair and remodeling. The μCh reduced the extracellular trap formation of anchored neutrophils at the very beginning (24 h) of implantation while increasing the number of live cells. Among the macrophages covered the surface of μCh over 7 days a major population polarized toward alternativelly activated phase (M2) which contrasted with control scaffolds where classically activated phase (M1) being dominant. The mesenchymal stem cells (MSCs) recruited to the μCh were significantly more than those to the control, and the event was correlated with the increased level of stem cell homing cytokine, stromal derived factor 1 (SDF1) sequestered to the μCh. Furthermore, the neo-blood vessel formation was more pronounced in the μCh, which was in line with the piling up of angiogenic factor, vascular endothelial growth factor (VEGF) in the μCh. Further assays on the protein sequestration to the μCh revealed that a set of chemokines involved in early pro-inflammatory responses were less found whereas representative adhesive proteins engaged in the cell-matrix interactions were significantly more captured. Ultimately, the fibrous capsule formation on the μCh was reduced with respect to the control, when assessed for up to 21 days, indicating less severe foreign body reaction. The tissue healing and regenerative capacity of the μCh was then confirmed in a critically sized bone model, where those series of events observed are essential to relay bone regeneration. The results over 6 weeks showed that the μCh significantly enhanced the early bone matrix deposition and accelerated bone regeneration. While more in-depth studies remain as to elucidate the underlying mechanisms for each biological event, the molecular, cellular and tissue reactions to the μCh were coherently favorable for the regeneration process of tissues, supporting the engineered scaffolds as potential therapeutic 3D platforms

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    The effectiveness of an enhanced recovery after surgery protocol in head and neck cancer surgery with free-flap reconstruction

    Get PDF
    PURPOSE: An enhanced recovery after surgery (ERAS) protocol incorporates up-to-date perioperative care principles; the primary aim in using an ERAS protocol is to reduce issues that delay the recovery and cause the complications. The aim of this study was to compare outcomes associated with head and neck cancer surgery with free-flap reconstruction before and after implementation of an ERAS protocol. METHODS: Outcomes were analyzed by dividing patients into 2 groups: 29 patients in the non-ERAS group and 60 patients in the ERAS group. The ERAS group performed a prospective observational cohort study of patients who underwent a head and neck cancer surgery with free-flap reconstruction in Ajou University Hospital from August 2015 to December 2017. The non-ERAS group retrospectively reviewed the medical records of patients who had undergone the same surgery from August 2012 to July 2015. RESULTS: Demographics, comorbidities, hospital length of stay (LOS), postoperative complications, starting time of rehabilitation, and postoperative periods before radiotherapy for the non-ERAS and ERAS groups were compared. Hospital LOS was significantly lower for patients whose care followed the ERAS protocol than for patients in the non-ERAS group (30.87 +/- 20.72 days vs. 59.66 +/- 40.43 days, P < 0.0001). CONCLUSION: In this study, hospital LOS was reduced through fast recovery after the implementation of the ERAS protocol. Therefore, the ERAS protocol appeared feasible and safe in head and neck cancer surgery with free-flap reconstruction

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Reliable and robust method for abdominal muscle mass quantification using CT/MRI: An explorative study in healthy subjects

    Get PDF
    BACKGROUND: Quantification of abdominal muscle mass by cross-sectional imaging has been increasingly used to diagnose sarcopenia; however, the technical method for quantification has not been standardized yet. We aimed to determine an optimal method to measure the abdominal muscle area. METHODS: Among 50 consecutive subjects who underwent abdominal CT and MRI for possible liver donation, total abdominal muscle area (TAMA) and total psoas muscle area (TPA) at the L3 inferior endplate level were measured by two blinded readers. Inter-scan agreement between CT and MRI and inter-reader agreement between the two readers were evaluated using intraclass correlation coefficient (ICC) and within-subject coefficient of variation (WSCV). To evaluate the effect of measurement level, one reader measured TAMA and TPA at six levels from the L2 to L4 vertebral bodies. RESULTS: TAMA was a more reliable biomarker than TPA in terms of inter-scan agreement (ICC: 0.928 vs. 0.788 for reader 1 and 0.853 vs. 0.821 for reader 2, respectively; WSCV: 8.3% vs. 23.4% for reader 1 and 10.4% vs. 22.3% for reader 2, respectively) and inter-reader agreement (ICC: 0.986 vs. 0.886 for CT and 0.865 vs. 0.669 for MRI, respectively; WSCV: 8.2% vs. 16.0% for CT and 11.6% vs. 29.7% for MRI, respectively). In terms of the measurement level, TAMA did not differ from the L2inf to L4inf levels, whereas TPA increased with a decrease in measurement level. CONCLUSIONS: TAMA is a better biomarker than TPA in terms of inter-scan and inter-reader agreement and robustness to the measurement level. CT was a more reliable imaging modality than MRI. Our results support the use of TAMA measured by CT as a standard biomarker for abdominal muscle area measurement

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    A Search for Dark Higgs Bosons

    Get PDF
    Recent astrophysical and terrestrial experiments have motivated the proposal of a dark sector with GeV-scale gauge boson force carriers and new Higgs bosons. We present a search for a dark Higgs boson using 516 fb-1 of data collected with the BABAR detector. We do not observe a significant signal and we set 90% confidence level upper limits on the product of the Standard Model-dark sector mixing angle and the dark sector coupling constant.Comment: 7 pages, 5 postscript figures, published version with improved plots for b/w printin
    corecore