218 research outputs found

    Biological roles of crop NADP-malic enzymes and molecular mechanisms involved in abiotic stress

    Get PDF
    The abiotic stress tolerance of plants is very important for plant growth, development, survival and functional performance. NADP-ME is one of the most important enzymes in plants. Studying the role that NADP-malic enzyme plays in many metabolisms may help researchers improve the plant abiotic tolerance. The studies on NADP-ME in plants focus on its activity under different stresses. The regulation of NADP-ME gene expression in transgenic plants and the mechanism about abiotic stress resistance are less. In this paper, we reviewed the characteristics of the activity and genes expression of NADP-ME under drought, salt and temperature stresses. We also focused on the role of NADP-ME when it resists these varying stresses and the mechanism on how it performs.Key words: Plant NADP-malic enzyme, abiotic stress, gene expression, molecular mechanism

    Ambient fabrication of flexible and large-area organic light-emitting devices using slot-die coating

    Get PDF
    The grand vision of manufacturing large-area emissive devices with low-cost roll-to-roll coating methods, akin to how newspapers are produced, appeared with the emergence of the organic light-emitting diode about 20 years ago. Today, small organic light-emitting diode displays are commercially available in smartphones, but the promise of a continuous ambient fabrication has unfortunately not materialized yet, as organic light-emitting diodes invariably depend on the use of one or more time- and energy-consuming process steps under vacuum. Here we report an all-solution-based fabrication of an alternative emissive device, a light-emitting electrochemical cell, using a slot-die roll-coating apparatus. The fabricated flexible sheets exhibit bidirectional and uniform light emission, and feature a fault-tolerant >1-μm-thick active material that is doped in situ during operation. It is notable that the initial preparation of inks, the subsequent coating of the constituent layers and the final device operation all could be executed under ambient air

    Observation of a ppb mass threshoud enhancement in \psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) decay

    Full text link
    The decay channel ψπ+πJ/ψ(J/ψγppˉ)\psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) is studied using a sample of 1.06×1081.06\times 10^8 ψ\psi^\prime events collected by the BESIII experiment at BEPCII. A strong enhancement at threshold is observed in the ppˉp\bar{p} invariant mass spectrum. The enhancement can be fit with an SS-wave Breit-Wigner resonance function with a resulting peak mass of M=186113+6(stat)26+7(syst)MeV/c2M=1861^{+6}_{-13} {\rm (stat)}^{+7}_{-26} {\rm (syst)} {\rm MeV/}c^2 and a narrow width that is Γ<38MeV/c2\Gamma<38 {\rm MeV/}c^2 at the 90% confidence level. These results are consistent with published BESII results. These mass and width values do not match with those of any known meson resonance.Comment: 5 pages, 3 figures, submitted to Chinese Physics

    Search for a Light Sterile Neutrino at Daya Bay

    Get PDF
    published_or_final_versio

    Determination of the number of J/ψ events with J/ψ → inclusive decays

    Get PDF
    postprin

    Measurement of the matrix element for the decay η′→ηπ +π -

    Get PDF
    The Dalitz plot of η⊃′→ηπ⊃+π⊃- decay is studied using (225.2±2.8)×106 J/ψ events collected with the BESIII detector at the BEPCII e⊃+e⊃- collider. With the largest sample of η⊃′ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also, the branching fraction of J/ψ→γη⊃′ is determined to be (4.84±0.03±0.24)×10⊃-3, where the first error is statistical and the second systematic. © 2011 American Physical Society.published_or_final_versio

    Higher-order multipole amplitude measurement in ψ ′→γχ c2

    Get PDF
    Using 106×106 ψ ′ events collected with the BESIII detector at the BEPCII storage ring, the higher-order multipole amplitudes in the radiative transition ψ ′→γχ c2→γπ +π -/γK +K - are measured. A fit to the χ c2 production and decay angular distributions yields M2=0.046±0. 010±0.013 and E3=0.015±0.008±0.018, where the first errors are statistical and the second systematic. Here M2 denotes the normalized magnetic quadrupole amplitude and E3 the normalized electric octupole amplitude. This measurement shows evidence for the existence of the M2 signal with 4.4σ statistical significance and is consistent with the charm quark having no anomalous magnetic moment. © 2011 American Physical Society.published_or_final_versio

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Diagnostic Utility of Pentraxin 3 Expression in Septic Cardiomyopathy: Findings from a Prospective Observational Study

    Get PDF
    Na Cui,1,2,&amp;ast; Xiao-Wei Lv,2,&amp;ast; Teng-Hao Shao,2 Zhan-Biao Yu,2 Zhi Chen,2 Tao Sun,2 Tie-Min Li,2 Jin-Wen Zhang,2 Zhen-Jie Hu1 1Department of Critical Care Medicine, The Fourth Affiliated Hospital of Hebei Medical University, Shijiazhuang, 050010, People’s Republic of China; 2Department of Critical Care Medicine, Affiliated Hospital of Hebei University, Baoding, 071000, People’s Republic of China&amp;ast;These authors contributed equally to this workCorrespondence: Zhen-Jie Hu, Department of Critical Care Medicine, The Fourth Affiliated Hospital of Hebei Medical University, No. 12, Jiankang Road, Shijiazhuang, 050010, People’s Republic of China, Tel +86 13933856908, Email [email protected]: The aim of this study is to investigate the expression levels of Pentraxin 3, PTX3 in patients with septic cardiomyopathy, SCM and evaluate its diagnostic potential for predicting SCM.Methods: A prospective observational study was conducted involving 122 patients diagnosed with septic shock between February 2023 and August 2024. Demographic and clinical data, along with plasma PTX3 concentrations were recorded. Participants were categorized into two groups based on the presence of SCM. PTX3 concentrations and their dynamic changes were compared between the groups. The correlations between PTX3 concentrations and other clinical indicators were analyzed, and the influencing factors associated with SCM development were assessed. The predictive performance of PTX3 for SCM was evaluated using receiver operating characteristic, ROC curves.Results: SCM was identified in 24.6% of the participants. Plasma PTX3 concentrations at admission and on day 3 were significantly higher in the SCM group compared to the non-SCM group, p &lt; 0.001. However, no significant differences were observed on day 7, p &gt; 0.05. PTX3 concentrations decreased over time in both groups. Plasma PTX3 concentrations were correlated with procalcitonin, lactate, myoglobin, troponin I, the elevated levels of troponin I on day 2 compared to admission, Sequential Organ Failure Assessment score, Acute Physiology and Chronic Health Evaluation II score, and intensive care unit length of stay. Elevated plasma PTX3 concentrations were identified as an independent risk factor for SCM development. The area under the ROC curve for PTX3 in predicting SCM was 0.784, p &lt; 0.001, with a cutoff value of 20.82 ng/mL, sensitivity of 0.767, and specificity of 0.707.Conclusion: Plasma PTX3 concentrations are markedly elevated in patients with SCM, indicating that PTX3 may serve as a reliable biomarker for the early diagnosis of SCM.Keywords: diagnosis, PTX3, sepsis, septic cardiomyopathy, septic shoc

    Independent measure of the neutrino mixing angle θ13 via neutron capture on hydrogen at Daya Bay

    Get PDF
    published_or_final_versio
    corecore