267 research outputs found

    PV single-phase grid-connected converter : dc-link voltage sensorless prospective

    Get PDF
    In this paper, a dc-link voltage sensorless control technique is proposed for single-phase two-stage grid-coupled photovoltaic (PV) converters. Matching conventional control techniques, the proposed scheme assigns the function of PV maximum power point tracking to the chopper stage. However, in the inverter stage, conventional techniques employ two control loops: outer dc-link voltage and inner grid current control loops. Diversely, the proposed technique employs only current control loop and mitigates the voltage control loop, thus eliminating the dc-link high-voltage sensor. Hence, system cost and footprint are reduced, and control complexity is minimized. Furthermore, the removal of the dc-link voltage loop proportional-integral controller enhances system stability and improves its dynamic response during sudden environmental changes. The system simulation is carried out, and an experimental rig is implemented to validate the proposed technique effectiveness. In addition, the proposed technique is compared with the conventional one under varying irradiance conditions at different dc-link voltage levels, illustrating the enhanced capabilities of the proposed technique

    Improved performance low-cost incremental conductance PV MPPT technique

    Get PDF
    Variable-step incremental conductance (Inc.Cond.) technique, for photovoltaic (PV) maximum power point tracking, has merits of good tracking accuracy and fast convergence speed. Yet, it lacks simplicity in its implementation due to the mathematical division computations involved in its algorithm structure. Furthermore, the conventional variable step-size, based on the division of the PV module power change by the PV voltage change, encounters steadystate power oscillations and dynamic problems especially under sudden environmental changes. In this study, an enhancement is introduced to Inc.Cond. algorithm in order to entirely eliminate the division calculations involved in its structure. Hence, algorithm implementation complexity is minimised enabling the utilisation of low-cost microcontrollers to cut down system cost. Moreover, the required real processing time is reduced, thus sampling rate can be improved to fasten system response during sudden changes. Regarding the applied step-size, a modified variable-step size, which depends solely on PV power, is proposed. The latter achieves enhanced transient performance with minimal steady-state power oscillations around the MPP even under partial shading. For proposed technique's validation, simulation work is carried out and an experimental set up is implemented in which ARDUINO Uno board, based on low-cost Atmega328 microcontroller, is employed

    Nonlinear Channel Estimation Error Effect on Capacity of MIMO System

    Get PDF
    This paper presents the effect of nonlinearity and the effect of estimation error on the channel capacity in MIMO system. We consider a nonlinear MIMO channel, and compare the capacity of Rayleigh MIMO channel model with estimation error with the nonlinear model, at different estimation errors. We consider the estimation error as Gaussian distribution. The simulation results show that the channel capacity of linear and nonlinear MIMO channels are sensitive to the channel estimation error, and due to the nonlinearity, the capacity is less than linear channel. Keywords: MIMO, MIMO Modeling, channel capacity, channel estimation error, nonlinear MIMO channel.

    Study of Multi Staging Operation of Swirling Fluidized Bed

    Get PDF
    The report is a description of the topic and the idea of the final year project as well as the plan and the steps that have been taken in order to carry out the project named: “Study of Multi Staging Operation of a Swirling Fluidized Bed”. Detailed design of a multi stage swirling fluidized bed that can be used for laboratory experimental purposes in UTP was provided with all the components, assemblies and functions descriptions. The design was evaluated for its efficiency and ability to meet flow requirements. Residence time distribution was investigated for several stages of swirling fluidized bed using a mathematical model that provides an F(t) function that depends on the number of stages, system phase shift, coefficient of exponent and the average residence time. The report contains a basic background about the swirling fluidized bed, the fluidization process, the definition of the main problem which centers on the residence time distribution for several stages of SFB, the objectives of the project, the methodology and the tasks to be taken in order to effectively achieve those objectives, a Gantt chart of the project life cycle as well as the results and the outcomes of the analysis

    High performance single-phase single-stage grid-tied PV current source inverter using cascaded harmonic compensators

    Get PDF
    In this paper, a single-phase single-stage photovoltaic (PV) grid-tied system is investigated. The conventional Pulse Width Modulated (PWM) voltage source inverter (VSI) is replaced by a PWM current source inverter (CSI) for its voltage boosting capabilities, inherent short-circuit proof and higher reliability features. Modeling, design and analysis of the considered CSI are presented altogether with enhanced proposed control loops aided with a modified PWM technique. DC-link even current harmonics are commonly reflected as low-order odd harmonics in the grid resulting in a poor quality grid current. In order to overcome the latter, a high performance Proportional Resonant Controller, applied in the inverter inner grid current loop, is proposed using cascaded resonant control units tuned at low-order frequencies to eliminate injected grid current harmonics. Hence, with a less-bulky smoothing inductor at the CSI DC-side, grid power quality and system efficiency are simultaneously improved. Simulation and experimental results verify the proposed controller effectiveness

    Continuous-input continuous-output current buck-boost DC/DC converters for renewable energy applications : modelling and performance assessment

    Get PDF
    Stand-alone/grid connected renewable energy systems (RESs) require direct current (DC)/DC converters with continuous-input continuous-output current capabilities as maximum power point tracking (MPPT) converters. The continuous-input current feature minimizes the extracted power ripples while the continuous-output current offers non-pulsating power to the storage batteries/DC-link. CUK, D1 and D2 DC/DC converters are highly competitive candidates for this task especially because they share similar low-component count and functionality. Although these converters are of high resemblance, their performance assessment has not been previously compared. In this paper, a detailed comparison between the previously mentioned converters is carried out as several aspects should be addressed, mainly the converter tracking efficiency, conversion efficiency, inductor loss, system modelling, transient and steady-state performance. First, average model and dynamic analysis of the three converters are derived. Then, D1 and D2 small signal analysis in voltage-fed-mode is originated and compared to that of CUK in order to address the nature of converters' response to small system changes. Finally, the effect of converters’ inductance variation on their performance is studied using rigorous simulation and experimental implementation under varying operating conditions. The assessment finally revels that D1 converter achieves the best overall efficiency with minimal inductor value

    A Simplified Double-Bundle Anterior Cruciate Ligament Reconstruction by the Three-Inside Technique With Two Suspension Buttons and One Interference Screw

    Get PDF
    In comparison with the single-bundle technique, double-bundle anterior cruciate ligament (ACL) reconstruction has proven its superiority regarding biomechanical studies and clinical outcomes in both rotational knee stability and anterior translation function. However, the complexity and risk of complications remain a great concern for the orthopaedic surgeon performing double-bundle ACL reconstruction. We present a simplified double-bundle ACL reconstruction by the 3-inside technique with 2 suspension buttons and 1 interference screw. The semitendinosus tendon is tripled to be the anteromedial (AM) bundle, whereas the gracilis is doubled for the posterolateral (PL) bundle. We perform a 3-socket approach with an inside-out femoral tunnel for the AM bundle, an outside-in femoral tunnel for the PL bundle, and a retrograde tibial socket for the tibial bundle. Thus, this technique is, simply, a combination of 2 procedures: one single all-inside method (for the AM bundle) and one outside-in method (for the PL bundle), with which most arthroscopic surgeons are familiar. The AM and PL bundles are fixed at 30° and 45°, respectively, using 2 suspension buttons and 1 interference screw. Our simplified technique could reduce surgical costs and minimize complications while maintaining isometric position and appropriate graft size for each patient

    Individualized medicine enabled by genomics in Saudi Arabia

    Full text link
    corecore