68 research outputs found

    Global Attractivity of Positive Periodic Solution for a Delayed Predator-Prey System with Diffusion and Impulses

    Get PDF
    By constructing a suitable Lyapunov functional, the global attractivity of positive periodic solutions for a delayed predator-prey system with diffusion and impulses is studied in this paper. Finally, an example and numerical analysis are given to show the effectiveness of the main results

    A Collaborative Filtering Recommendation Algorithm with Improved Similarity Calculation

    Get PDF
    Abstract In order to improve the accuracy of the proposed algorithm in collaborative filtering recommendation system, an Improved Pearson collaborative filtering (IP-CF) algorithm is proposed in this paper. The algorithm uses the user portrait, item characteristics and data of user behavior to compute the baseline predictors model. Instead of the traditional algorithm’s similarity calculation, the prediction model is used to improve the accuracy of the recommendation algorithm. Experimental results on Moivelens dataset show that the IP-CF algorithm significantly improves the accuracy of the recommended results, and the RMSE and MAE evaluation results are better than the traditional algorithms.</jats:p

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Blind source separation of coexisting background in Raman spectra

    Full text link
    corecore