4,796 research outputs found

    Prior events predict cerebrovascular and coronary outcomes in the PROGRESS trial

    Get PDF
    <p><b>Background and Purpose:</b> The relationship between baseline and recurrent vascular events may be important in the targeting of secondary prevention strategies. We examined the relationship between initial event and various types of further vascular outcomes and associated effects of blood pressure (BP)–lowering.</p> <p><b>Methods:</b> Subsidiary analyses of the Perindopril Protection Against Recurrent Stroke Study (PROGRESS) trial, a randomized, placebo-controlled trial that established the benefits of BP–lowering in 6105 patients (mean age 64 years, 30% female) with cerebrovascular disease, randomly assigned to either active treatment (perindopril for all, plus indapamide in those with neither an indication for, nor a contraindication to, a diuretic) or placebo(s).</p> <p><b>Results:</b> Stroke subtypes and coronary events were associated with 1.5- to 6.6-fold greater risk of recurrence of the same event (hazard ratios, 1.51 to 6.64; P=0.1 for large artery infarction, P<0.0001 for other events). However, 46% to 92% of further vascular outcomes were not of the same type. Active treatment produced comparable reductions in the risk of vascular outcomes among patients with a broad range of vascular events at entry (relative risk reduction, 25%; P<0.0001 for ischemic stroke; 42%, P=0.0006 for hemorrhagic stroke; 17%, P=0.3 for coronary events; P homogeneity=0.4).</p> <p><b>Conclusions:</b> Patients with previous vascular events are at high risk of recurrences of the same event. However, because they are also at risk of other vascular outcomes, a broad range of secondary prevention strategies is necessary for their treatment. BP–lowering is likely to be one of the most effective and generalizable strategies across a variety of major vascular events including stroke and myocardial infarction.</p&gt

    Searching for keV Sterile Neutrino Dark Matter with X-ray Microcalorimeter Sounding Rockets

    Full text link
    High-resolution X-ray spectrometers onboard suborbital sounding rockets can search for dark matter candidates that produce X-ray lines, such as decaying keV-scale sterile neutrinos. Even with exposure times and effective areas far smaller than XMM-Newton and Chandra observations, high-resolution, wide field-of-view observations with sounding rockets have competitive sensitivity to decaying sterile neutrinos. We analyze a subset of the 2011 observation by the X-ray Quantum Calorimeter instrument centered on Galactic coordinates l = 165, b = -5 with an effective exposure of 106 seconds, obtaining a limit on the sterile neutrino mixing angle of sin^2(2 theta) < 7.2e-10 at 95% CL for a 7 keV neutrino. Better sensitivity at the level of sin^2(2 theta) ~ 2.1e-11 at 95\% CL for a 7 keV neutrino is achievable with future 300-second observations of the galactic center by the Micro-X instrument, providing a definitive test of the sterile neutrino interpretation of the reported 3.56 keV excess from galaxy clusters.Comment: 13 pages, 13 figures, submitted to Ap

    Prime mover or fellow traveller:25-hydroxy vitamin D’s seasonal variation, cardiovascular disease and death in the Scottish Heart Health Extended Cohort (SHHEC)

    Get PDF
    BACKGROUND: Theoretical links between seasonal lack of sunlight, hypovitaminosis D and excess cardiovascular disease and death prompted our adding novel to conventional cohort analyses. METHODS: We tested three postulates on 13 224 Scottish Heart Health Extended Cohort participants, assayed for 25-hydroxyvitamin D (25OHD) and followed for 22 years. (i) Endpoints enumerated by month of occurrence mirror annual seasonal oscillation in 25OHD. (ii) Endpoint seasonality is increased in people with below median 25OHD. (iii) Low 25OHD predicts endpoints independently of major risk factors. RESULTS: Baseline median 25OHD level was 36.4 (other quartiles 26.7, 51.7) nmol/l. The March trough was half the August peak, both well after seasonal solstices. (i) There was no demonstrable monthly variation in First Cardiovascular Event (n = 3307). Peaks and troughs for All Death and Cardiovascular Death (n = 2987, 1350) were near the solstices, earlier than extremes of 25OHD. (ii) Endpoint variability showed no difference between those above and below median 25OHD. (iii) Cox model hazard ratios (HR), by decreasing 25OHD, increased modestly and nonspecifically for all endpoints examined, with no threshold, the gradients diminishing by  ∼ : 60% following multiple adjustment. For Cardiovascular Disease, HR, by 20 (∼SD) nmol/l decrease, = 1.224 (1.175, 1.275) adjusted for age and sex; additionally adjusted for family history, deprivation index, smoking, systolic blood pressure, total and HDL cholesterol, = 1.093 (1.048, 1.139); All Deaths = 1.238 (1.048, 1.139) and 1.098 (1.050, 1.149). 25OHD made no independent contribution to cardiovascular discrimination and reclassification. CONCLUSIONS: Our analyses challenge vitamin D's alleged role as major prime mover in cardiovascular disease and mortality.</p

    The Pioneer Anomaly

    Get PDF
    Radio-metric Doppler tracking data received from the Pioneer 10 and 11 spacecraft from heliocentric distances of 20-70 AU has consistently indicated the presence of a small, anomalous, blue-shifted frequency drift uniformly changing with a rate of ~6 x 10^{-9} Hz/s. Ultimately, the drift was interpreted as a constant sunward deceleration of each particular spacecraft at the level of a_P = (8.74 +/- 1.33) x 10^{-10} m/s^2. This apparent violation of the Newton's gravitational inverse-square law has become known as the Pioneer anomaly; the nature of this anomaly remains unexplained. In this review, we summarize the current knowledge of the physical properties of the anomaly and the conditions that led to its detection and characterization. We review various mechanisms proposed to explain the anomaly and discuss the current state of efforts to determine its nature. A comprehensive new investigation of the anomalous behavior of the two Pioneers has begun recently. The new efforts rely on the much-extended set of radio-metric Doppler data for both spacecraft in conjunction with the newly available complete record of their telemetry files and a large archive of original project documentation. As the new study is yet to report its findings, this review provides the necessary background for the new results to appear in the near future. In particular, we provide a significant amount of information on the design, operations and behavior of the two Pioneers during their entire missions, including descriptions of various data formats and techniques used for their navigation and radio-science data analysis. As most of this information was recovered relatively recently, it was not used in the previous studies of the Pioneer anomaly, but it is critical for the new investigation.Comment: 165 pages, 40 figures, 16 tables; accepted for publication in Living Reviews in Relativit

    Analisis Penerapan Sistem Akuntansi Penjualan Kredit Dan Penerimaan Kas Dalam Mendukung Pengendalian Intern Perusahaan (Studi Kasus PT. Smart Tbk Refinery Surabaya)

    Full text link
    System of selling credit accounting and system of cash receiving from account receivable is the source of life to achieving company goals. This research on the system of credit sales and cash receipts to support the company internal control. This research was conducted at PT. SMART Tbk Refinery Surabaya. PT. SMART Tbk Refinery Surabaya only selling cooking oil in the form of branded product and trading product on credit. PT. SMART Tbk Refinery Surabaya still has any weakness on system of selling credit accounting and system of cash receiving from account receivable, some of the sales transaction activity that occurred less supportive of the company\u27s internal control. This study aims to provide information to companies about the advantages and weakness of credit sales accounting system and cash receipts that have been applied by the company

    JLab Measurement of the 4^4He Charge Form Factor at Large Momentum Transfers

    Get PDF
    The charge form factor of ^4He has been extracted in the range 29 fm2^{-2} Q277\le Q^2 \le 77 fm2^{-2} from elastic electron scattering, detecting 4^4He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second diffraction minimum, which was predicted in the Q2Q^2 range of this experiment, and rule out conclusively long-standing predictions of dimensional scaling of high-energy amplitudes using quark counting.Comment: 4 pages, 2 figure

    Measurement of the Target-Normal Single-Spin Asymmetry in Quasi-Elastic Scattering from the Reaction 3^3He(e,e)^\uparrow(e,e^\prime)

    Full text link
    We report the first measurement of the target single-spin asymmetry, AyA_y, in quasi-elastic scattering from the inclusive reaction 3^3He(e,e)^{\uparrow}(e,e^\prime) on a 3^3He gas target polarized normal to the lepton scattering plane. Assuming time-reversal invariance, this asymmetry is strictly zero for one-photon exchange. A non-zero AyA_y can arise from the interference between the one- and two-photon exchange processes which is sensitive to the details of the sub-structure of the nucleon. An experiment recently completed at Jefferson Lab yielded asymmetries with high statistical precision at Q2=Q^{2}= 0.13, 0.46 and 0.97 GeV2^{2}. These measurements demonstrate, for the first time, that the 3^3He asymmetry is clearly non-zero and negative with a statistical significance of (8-10)σ\sigma. Using measured proton-to-3^{3}He cross-section ratios and the effective polarization approximation, neutron asymmetries of -(1-3)% were obtained. The neutron asymmetry at high Q2Q^2 is related to moments of the Generalized Parton Distributions (GPDs). Our measured neutron asymmetry at Q2=0.97Q^2=0.97 GeV2^2 agrees well with a prediction based on two-photon exchange using a GPD model and thus provides a new, independent constraint on these distributions

    The SPLIT Research Agenda 2013

    Full text link
    This review focuses on active clinical research in pediatric liver transplantation with special emphasis on areas that could benefit from studies utilizing the SPLIT infrastructure and data repository. Ideas were solicited by members of the SPLIT Research Committee and sections were drafted by members of the committee with expertise in those given areas. This review is intended to highlight priorities for clinical research that could successfully be conducted through the SPLIT collaborative and would have significant impact in pediatric liver transplantation.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/98814/1/petr12090.pd

    Strangeness Enhancement in Cu+Cu and Au+Au Collisions at \sqrt{s_{NN}} = 200 GeV

    Get PDF
    We report new STAR measurements of mid-rapidity yields for the Λ\Lambda, Λˉ\bar{\Lambda}, KS0K^{0}_{S}, Ξ\Xi^{-}, Ξˉ+\bar{\Xi}^{+}, Ω\Omega^{-}, Ωˉ+\bar{\Omega}^{+} particles in Cu+Cu collisions at \sNN{200}, and mid-rapidity yields for the Λ\Lambda, Λˉ\bar{\Lambda}, KS0K^{0}_{S} particles in Au+Au at \sNN{200}. We show that at a given number of participating nucleons, the production of strange hadrons is higher in Cu+Cu collisions than in Au+Au collisions at the same center-of-mass energy. We find that aspects of the enhancement factors for all particles can be described by a parameterization based on the fraction of participants that undergo multiple collisions

    High pTp_{T} non-photonic electron production in pp+pp collisions at s\sqrt{s} = 200 GeV

    Get PDF
    We present the measurement of non-photonic electron production at high transverse momentum (pT>p_T > 2.5 GeV/cc) in pp + pp collisions at s\sqrt{s} = 200 GeV using data recorded during 2005 and 2008 by the STAR experiment at the Relativistic Heavy Ion Collider (RHIC). The measured cross-sections from the two runs are consistent with each other despite a large difference in photonic background levels due to different detector configurations. We compare the measured non-photonic electron cross-sections with previously published RHIC data and pQCD calculations. Using the relative contributions of B and D mesons to non-photonic electrons, we determine the integrated cross sections of electrons (e++e2\frac{e^++e^-}{2}) at 3 GeV/c<pT< c < p_T <~10 GeV/cc from bottom and charm meson decays to be dσ(Be)+(BDe)dyeye=0{d\sigma_{(B\to e)+(B\to D \to e)} \over dy_e}|_{y_e=0} = 4.0±0.5\pm0.5({\rm stat.})±1.1\pm1.1({\rm syst.}) nb and dσDedyeye=0{d\sigma_{D\to e} \over dy_e}|_{y_e=0} = 6.2±0.7\pm0.7({\rm stat.})±1.5\pm1.5({\rm syst.}) nb, respectively.Comment: 17 pages, 17 figure
    corecore